Known issues
Previous  Top  Next


1.   The http://localhost/XML-DA/SAEAutomation.SNMPOpcServerDA.3.asmx test page is not available.

Recommendation A: Please make sure that COM Security for ASP.NET is set correctly.

Recommendation B: Please make sure that the SAEAUT SNMP OPC Server is installed on your computer correctly.

Recommendation C: Please make sure that your Web Service link is written right.

Recommendation D: Please make sure that the Internet Information Services (IIS) is started.

Recommendation E: Please make sure that .asmx file extension is registered in IIS server.

Recommendation F: Please make sure that Microsoft .NET Framework 1.1 or higher is installed on your computer correctly (you can see if .NET Framework is installed via Administrative Tools panel). If so, try to reinstall .NET Framework. You can download it at:
http://www.microsoft.com/downloads/details.aspx?FamilyID=262d25e3-f589-4842-8157-034d1e7cf3a3&displaylang=en

 
2.A MIB file is not possible to load through MIB Browser (Off-Line).  

This feature is available only in the version SAEAUT SNMP OPC Server, Professional.

There are various mal-formed MIB files which are used in the SNMP devices all over the world. Therefore, we cannot warrant that each available MIB file will be parsed and loaded successfully by MIB Browser (Off-Line).

There is a possibility to contact us and send your existing projects to our company. We can try to convert these existing projects to new structure.

4.The SAEAUT SNMP OPC Server data are not available via OPC UA COM Wrapper interface.  

Please refer to the document Configuring DCOM for using of OPC UA COM Wrapper with OPC servers from SAE-Automation, Ltd. that describes DCOM settings in detail - available in Windows Start ð SAEAUT SNMP OPC Server ð Configuring OPC UA COM Wrapper for SAE products.

You can download the latest version of this white paper from the following link http://www.saeautom.sk/download/opcuaforsaeproducts.pdf.

5. Disconecting from SNMPRuntime when working with OPC DA and XML DA Client

It is not enough to disconect from SNMP OPC server by running OPC DA and XML DA client. It is necessary to stop the client. Other way SNMPRuntime.exe process continues to run.    



.


 


Send feedback on this topic.